Specifications The laser vector technique is a major break through in laser measurement. It is easy to setup and to operate. It is very efficient and time saving. Usually, the volumetric positioning errors, 3 displacement errors, 6 straightness errors and 3 squareness errors, in a working volume of 1 to 3 cubic meters can be measured in 2-4 hours. The volumetric positioning error compensation files can be generated automatically for most of the major controllers. Even for a large gantry machine, most of the measurements can be done in one dayinstead of one week by conventional interferometers. The equipment is compact and can be fitted into 2 small carrying cases. For various applications and requirements, there are 4 models MCV-5002 to MCV-5005 to choose from. Linear displacement error (top), yaw angular errors (middle), and pitch angular errors (bottom)of x-axis. Displacement error Yaw error Pitch error