OPTODYNE's   RT-100A   Automatic   Rotary   Table Calibration    Package    is   an   add-on   to   Optodyne's MCV-2002   Linear   and   Angular   Machine   Calibration Instrument  (or  the  enhanced  MCV-4000  model).  The combined system can be used to calibrate rotary tables or stages    with    high    accuracy.    Optodyne's    method    is different  from  the  conventional  comparative  approach using  a  laser  interferometer,  where  the  test  device  is compared  to the  known  inaccuracies  in  a  master  rotary calibrator.   This   comparative   approach   is   both   very expensive and difficult to use. Optodyne's machine calibration instruments are based on our proprietary and patented Laser Doppler Displacement Meter (LDDM) Technology. The dual-beam laser system can be used by itself to measure a rotational angle up to ± 10 degrees. With the supplied small turntable, the angular measurement  range  can  be  extended  to  360  degrees  in increments  up  to  10  degrees.  Hence,  the  combinations can be used to calibrate rotary tables or stages. MAJOR FEATURES AND BENEFITS •   Uses Optodyne's standard dual-beam laser system. •   High accuracy and repeatability. •   Elimination of the expensive, calibrated indexing table. •   Easy and fast to set up and use. •   True angular measurement (centering, runout, wobble, parallelism, co-axial alignment and other set up inaccuracies not critical). •   Compact and very affordable. MAJOR APPLICATIONS •   Calibration of CNC machine tools rotary axis. •   Calibration of rotary tables or stages. •   Quality control maintenance. •   Compensation of rotary position errors.